ROHDE & SCHWARZ SMU200A REPAIR and ROHDE & SCHWARZ SMU200A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the ROHDE & SCHWARZ SMU200A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ SMU200A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   ROHDE & SCHWARZ SMU200A (1141.2005.02)   Description / Specification:   Spec Sheet 
ROHDE & SCHWARZ SMU200A 2.2 /3 /4 or 6 GHz Vector Signal Generator

The R&S SMU200A (1141.2005.02) Vector Signal Generator has been designed to meet all requirements encountered in research and development of modern communications systems as well as in their production. Due to its modular design, the R&S SMU200A can be optimally adapted to the requirements of different applications. The first RF path can be equipped with one of the four available frequency options. The upper frequency limit of 2.2 GHz/3 GHz/4 GHz or 6 GHz is user-selectable. In addition, a second RF path can be installed with upper frequency limits of 2.2 GHz and 3 GHz. The lower frequency limit of all frequency options is 100 kHz. Specifications. Frequency range: 100 kHz to 2.2 GHz / 3 GHz / 4 GHz / 6 GHz. Setting time: <3 ms. Setting time in List mode: <450 µs. Level Range: –145 dBm to +13 dBm (PEP, 3 GHz). SSB phase noise (20 kHz carrier offset, 1 Hz measurement bandwidth): typ. –135 dBc. RF modulation bandwidth Using external I/Q inputs: 200 MHz. Supported modulation types: AM (DC to 500 kHz), Pulse (0 kHz to 100 kHz), ASK (0 % to 100 %), FSK (MSK, 2FSK, 4FSK), PSK (BPSK, QPSK, OQPSK, pi/2 DBPSK, pi/4 DQPSK, pi/8 D8PSK, pi/4 QPSK, 8PSK, 8PSK EDGE), QAM (16QAM, 32QAM, 64QAM, 256QAM, 1024QAM). Interfaces: IEEE 488.2, LAN (100BaseT), 3 × USB, 1 × USB slave, VGA. Options. SMU-B102 (1141.8503.02), RF Path A 100 kHz to 2.2 GHz. SMU-B103 (1141.8603.02), RF Path A 100 kHz to 3 GHz. SMU-B104 (1141.8703.02), RF Path A 100 kHz to 4 GHz. SMU-B106 (1141.8803.02), RF Path A 100 kHz to 6 GHz. SMU-B20 (1142.0006.02), RF Path A FM/phaseM Modulator. SMU-B22 (1160.5006.02), RF Path A FM/phaseM Modulator and Low Phase Noise. SMU-B30 (1159.7444.02), RF Path A Overvoltage Protection. SMU-B31 (1159.8011.02), RF Path A High-Power Output. SMU-B32 (1160.0256.02), RF Path A Overvoltage Protection and High-Power Output. SMU-B202 (1141.9400.02), RF Path B 100 kHz to 2.2 GHz. SMU-B203 (1141.9500.02), RF Path B 100 kHz to 3 GHz. SMU-B35 (1160.0633.02), RF Path B Overvoltage Protection.SMU-B36 (1160.1000.02), RF Path B High-Power Output. SMU-B37 (1160.1400.02), RF Path B Overvoltage Protection and High-Power Output.



 

Standard Calibration $700.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ SMU200A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your ROHDE & SCHWARZ SMU200A REPAIR and/or ROHDE & SCHWARZ SMU200A 2.2 /3 /4 or 6 GHz Vector Signal Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*